Mã lỗi 1510, 1530, 1550 , 1570 — Kyocera FSC5400DN

Code: 1510, 1530, 1550 , 1570

Description: PF warm air heater (side blower) high temperature error* (Option paper feeder) A temperature higher than 85°C/185°F is detected. *: Multi purpose feeder only 1510: Paper feeder 1 1530: Paper feeder 2 1550: Paper feeder 3 1570: Paper feeder 4
Causes: The inlet of side blower assembly is blocked by paper pieces or the like. Defective harness between PF warm air fan motor 1 and PF main PWB (YC11), or improper connector insertion. Shorted PF thermistor 1. Defective PF warm air fan motor 1. Defective PF main PWB. Defective engine PWB.
Remedy: The inlet of side blower assembly is blocked by paper pieces or the like. Check visually and remove it, if any (Refer to the service manual for the paper feeder).
Defective harness between PF warm air fan motor 1 and PF main PWB (YC11), or improper connector insertion. Reinsert the connector. Also check for continuity within the connector harness. If none, remedy or replace the harness. (Refer to the service manual for the paper feeder).
Shorted PF thermistor 1. Replace the PF thermistor 1. (Refer to the service manual for the paper feeder).
Defective PF warm air fan motor 1. Replace the PF warm air fan motor 1 (Refer to the service manual for the paper feeder).
Defective PF main PWB. Replace the PF main PWB (Refer to the service manual for the paper feeder).
Defective engine PWB. Replace the engine PWB.

← Xem tất cả mã lỗi Kyocera FSC5400DN