Code: 2300
Description: Fuser motor error The ready signal cannot be detected within 5 seconds after the fuser motor turns on.
Causes: Defective harness between fuser motor and engine PWB (YC605), or improper connector insertion. Defective drive transmission system of the fuser motor. Defective fuser motor. Defective engine PWB.
Remedy: Defective harness between fuser motor and engine PWB (YC605), or improper connector insertion. Reinsert the connector. Also check for continuity within the connector harness. If none, remedy or replace the harness.
Defective drive transmission system of the fuser motor. Check if the gears rotate smoothly. If not, grease the bushings and gears. Check for broken gears and replace if any.
Defective fuser motor. Replace the fuser motor.
Defective engine PWB. Replace the engine PWB.
Defective drive transmission system of the fuser motor. Check if the gears rotate smoothly. If not, grease the bushings and gears. Check for broken gears and replace if any.
Defective fuser motor. Replace the fuser motor.
Defective engine PWB. Replace the engine PWB.