Code: 5300
Description: Eraser lamp broken detection
• The current at the correct level is not detected when ASIC (U8) on the engine controller PWB (KP-992) generates the signal to activate the eraser lamp.
• The current at the correct level is not detected when ASIC (U8) on the engine controller PWB (KP-992) generates the signal to activate the eraser lamp.
Causes: Defective engine controller PWB (KP-992). Defective drum unit (eraser lamp or drum PWB [KP- 813]). Defective harness (2BM2864) between engine controller PWB (KP-992) and drum unit, or poor contact of the connector terminals.
Remedy: Replace the engine controller PWB (KP- 992). Replace the drum unit. Check the continuity of the harness (2BM2864). Check the insertion of connectors.