Code: 0122
Description: EEPROM read error (drum PWB C)
• When data is transmitted to the EEPROM on drum PWB C, the ACK signal is not returned within 1 s.
• When data is transmitted to the EEPROM on drum PWB C, the ACK signal is not returned within 1 s.
Causes: Poor contact in the connector terminals.
Remedy: Poor contact in the connector terminals. Check the connection of connector YC10 on the engine controller PWB and the continuity across the connector terminals. Repair or replace if necessary.
Defective drum PWB C. Replace the cyan process unit.
Defective drum PWB C. Replace the cyan process unit.