Code: 0123
Description: EEPROM read error (drum PWB M)
• When data is transmitted to the EEPROM on drum PWB M, the ACK signal is not returned within 1 s.
• When data is transmitted to the EEPROM on drum PWB M, the ACK signal is not returned within 1 s.
Causes: Poor contact in the connector terminals. Defective drum PWB M.
Remedy: Poor contact in the connector terminals. Check the connection of connector YC11 on the engine controller PWB and the continuity across the connector terminals. Repair or replace if necessary.
Defective drum PWB M. Replace the magenta process unit.
Defective drum PWB M. Replace the magenta process unit.