Code: 0420
Description: Paper feeder communication error 1 (upper of optional paper feeder PF- 640)
• Reception is not normally completed even after 40 times of retry at startup or 5 times of retry in normal operation.
• Reception is not normally completed even after 40 times of retry at startup or 5 times of retry in normal operation.
Causes: Poor contact in the connector terminals. Defective engine controller PWB. Defective upper of optional paper feeder PF-640.
Remedy: Poor contact in the connector terminals. Check the connection of connector YC27 on the engine controller PWB. Repair or replace if necessary.
Defective engine controller PWB. Replace the engine controller PWB.
Defective upper of optional paper feeder PF-640. Replace the paper feeder with another unit and check the operation. If the operation is normal, replace or repair the upper of the optional paper feeder PF-640.
Defective engine controller PWB. Replace the engine controller PWB.
Defective upper of optional paper feeder PF-640. Replace the paper feeder with another unit and check the operation. If the operation is normal, replace or repair the upper of the optional paper feeder PF-640.