Thương hiệu phân phối chính hãng
Giỏ hàng

Mã lỗi C100 — Kyocera KM1505

Code: C100

Description: Exposure lamp problem
• Check the CCD input value for the lighting status of the exposure lamp 100 ms after the exposure lamp is lit and the carriage is moved to the shading position. If the exposure lamp does not light, turn off the lamp. After 500 ms, light the lamp again and, a further 500 ms later, check the CCD input. The exposure lamp does not light after 5 retries.
Causes: Poor contact of the connector terminals. Defective exposure lamp. Defective main PCB or inverter PCB. Incorrect shading position. CCD PCB output problem.
Remedy: Check the connection of connector CN12 on the main PCB, and the continuity across the connector terminals. Repair or replace if necessary. Replace the exposure lamp. Replace the main PCB or inverter PCB and check for correct operation. Adjust the position of the contact glass (shading plate). If the problem still occurs, replace the scanner home position switch. Replace the ISU.

← Xem tất cả mã lỗi Kyocera KM1505

Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin
Đăng ký nhận bản tin
Nhận ưu đãi sớm nhất khi chương trình diễn ra

Đăng ký nhận bản tin

Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này. Chính sách cookie