Code: 52
Description: Hot roller lamp fullpower operation error When full-power operation occurs during reheating, the main motor is not running and the difference between the current temperature and that of 60 seconds ago is 18°C or less.
Causes: Hot roller thermistor, hot roller lamp connector, MCU