Code: C401
Description: Polygon motor steady-state problem
• The polygon motor rotation is not stable for 400 ms after the polygon motor rotation has been stabilized.
• The polygon motor rotation is not stable for 400 ms after the polygon motor rotation has been stabilized.
Causes: Poor contact of the connector terminals. Defective polygon motor. Defective power source PCB.
Remedy: Check the connection of connector CN3 on the main PCB and the continuity across the connector terminals. Remedy or replace if necessary. Replace the LSU. Check if 24 V DC is present at CN1-2 on the power source PCB. If not, replace the power source PCB.