Mã lỗi C100 — Kyocera KM1530

Code: C100

Description: Exposure lamp problem
• Check the CCD input value for the lighting status of the exposure lamp 100 ms after the exposure lamp is lit and the carriage is moved to the shading position. If the exposure lamp does not light, turn off the lamp. After 500 ms, light the lamp again and, a further 500 ms later, check the CCD input. The exposure lamp does not light after 5 retries.
Causes: Poor contact of the connector terminals. Defective exposure lamp. Defective main PCB. Incorrect shading position. CCD PCB output problem.
Remedy: Check the connection of connectors CN24, CN23, CN22 and CN3 on the main PCB, and the continuity across the connector terminals. Repair or replace if necessary. Replace the exposure lamp or inverter PCB. Replace the main PCB and check for correct operation. Adjust the position of the contact glass (shading plate). If the problem still occurs, replace the scanner home position switch. Replace the ISU.