Code: C401
Description: Polygon motor steady-state problem
• The polygon motor rotation is not stable for 400 ms after the polygon motor rotation has been stabilized.
• The polygon motor rotation is not stable for 400 ms after the polygon motor rotation has been stabilized.
Causes: Poor contact of the polygon motor connector terminals. Defective power source PCB.
Remedy: Reinsert the connector. Also check for continuity within the connector cable. If none, repair or replace the cable. Check if 24 V DC is present at CN3-1 and CN3-2 on the power source PCB. If not, replace the power source PCB.