Code: C400
Description: Polygon motor synchronization problem
• The polygon motor does not reach the stable speed within 15 s of the START signal turning on.
• The polygon motor does not reach the stable speed within 15 s of the START signal turning on.
Causes: Poor contact in the polygon motor connector terminals. Defective polygon motor. Defective engine PCB.
Remedy: Reinsert the connector. Also check for continuity within the connector cable. If none, remedy or replace the cable. Replace the LSU. Replace the engine PCB and check for correct operation.