Code: C4000
Description: Polygon motor synchronization problem The polygon motor does not reach the stable speed within 20 s of the START signal turning on.
Causes: Poor contact in the polygon motor connector terminals. Defective polygon motor. Defective engine PWB.
Remedy: Poor contact in the polygon motor connector terminals. Reinsert the connector. Also check for continuity within the connector cable. If none, remedy or replace the cable. Defective polygon motor. Replace the LSU. Defective engine PWB. Replace the engine PWB and check for correct operation.