Code: C0140
Description: Backup memory data problem (main PCB EEPROM)
• Data in the specified area of the backup memory does not match the specified values.
• Data in the specified area of the backup memory does not match the specified values.
Causes: Problem with the backup memory data. Defective EEPROM.
Remedy: Turn safety switch off and back on and run maintenance item U020 to set the contents of the backup memory data again. If the C0140 is displayed after re-setting the backup memory contents, replace the EEPROM or main PCB.