Code: C0210
Description: Communication problem between the main board (KP-5191) and engine board (KP-5238)
• When the power is turned on, the machine does not detect the low level of SBSY and the high level of SDIR for three seconds.
• When the power is turned on, the machine does not detect the low level of SBSY and the high level of SDIR for three seconds.
Causes: Poor contact in the connector terminals. Defective main board (KP-5191) or engine board (KP-5238).
Remedy: Check the connection of connectors YC7 on the main board (KP-5191) and YC3 on the engine board (KP-5238), and the continuity across the connector terminals. Repair or replace if necessary. Replace the main board (KP-5191) or engine board (KP-5238) and check for correct operation.