Code: C6050
Description: Abnormally low fixing unit thermistor temperature • The fixing temperature remains below 90C/194F for 1 s.
Causes: Poor contact in the thermistor connector terminals. Broken thermistor wire. Thermistor installed incorrectly. Thermal cutout triggered. Heater lamp installed incorrectly. Broken heater lamp wire.
Remedy: Check the connection of connector YC4 on the power supply board and the continuity across the connector terminals. Repair or replace if necessary. Measure the resistance. If it is ∞Ω, replace the thermistor. Check and reinstall if necessary. Check for continuity. If none, replace the thermal cutout. Check and reinstall if necessary. Check for continuity. If none, replace the heater lamp.