Code: C600
Description: Broken fixing heater wire
• In fixing warm-up, the time to reach 50°C/122 °F exceeds 13.5 s, the time to reach 100°C/212 °F exceeds 10 s, the time to reach the primary stabilization exceeds 10 s or the time to reach the secondary stabilization exceeds 24 s.
• In fixing warm-up, the time to reach 50°C/122 °F exceeds 13.5 s, the time to reach 100°C/212 °F exceeds 10 s, the time to reach the primary stabilization exceeds 10 s or the time to reach the secondary stabilization exceeds 24 s.
Causes: Poor contact in the thermistor connector terminals. Fixing thermistor installed incorrectly. Fixing thermostat triggered. Fixing heater M or S installed incorrectly. Broken fixing heater M or S wire.
Remedy: Reinsert the connector. Also check for continuity within the connector cable. If none, remedy or replace the cable. Check and reinstall if necessary. Check for continuity. If none, replace the fixing thermostat. Check and reinstall if necessary. Check for continuity. If none, replace the heater lamp.