Code: C610
Description: Broken fixing heater wire
• Warm-up does not end within 90 s.
• The secondary stabilization fixing temperature drops to 100°C/212°F or below.
• The fixing temperature remains below 40˚C/104˚F for 7 s or longer after the fixing heaters have been turned on.
• Warm-up does not end within 90 s.
• The secondary stabilization fixing temperature drops to 100°C/212°F or below.
• The fixing temperature remains below 40˚C/104˚F for 7 s or longer after the fixing heaters have been turned on.
Causes: Fixing heater installed incorrectly. Broken fixing heater wire. Poor contact in the fixing unit thermistor connector terminals. Broken fixing unit thermistor wire. Fixing unit thermistor installed incorrectly. Fixing unit thermostat triggered.
Remedy: Check and reinstall if necessary. Check for continuity. If none, replace fixing heater. Check the connection of connector CN12 on the main PCB and the continuity across the connector terminals. Remedy or replace if necessary. Measure the resistance. If it is ∞Ω, replace the fixing unit thermistor. Check and reinstall if necessary. Check for continuity. If none, replace the fixing unit thermostat. Check the operation of the cooling fan and repair if necessary.