Code: C6050
Description: Abnormally low fuser thermistor center temperature Fuser thermistor 2 is detected 100C/ 212F less than 1 s continuously during copying.
Causes: Defective fuser heater M or S. Installation defectiveness on fuser thermistor 2. Defective PWB.
Remedy: Defective fuser heater M or S. Replace the fuser heater M or S.
Installation defectiveness on fuser thermistor 2. Check the mounting state of the fuser thermistor 2. If any problem is found, repair it.
Defective PWB. Replace the power source PWB or engine PWB and check for correct operation.
Installation defectiveness on fuser thermistor 2. Check the mounting state of the fuser thermistor 2. If any problem is found, repair it.
Defective PWB. Replace the power source PWB or engine PWB and check for correct operation.