Code: C4010
Description: Polygon motor steady-state problem • When high-speed rotation from lowspeed rotation is requested, the motor does not become stable even after 20 s.
Causes: Poor contact in the polygon motor connector terminals. Defective polygon motor. Defective power source PCB.
Remedy: Reinsert the connector. Also check for continuity within the connector cable. If none, remedy or replace the cable. Replace the LSU. Check if 24 V DC is supplied to YC2-1 on the main PCB. If not, replace the power source PCB. Check if 24 V DC is output from YC8-10 on the main PCB. If not, replace the main PCB.