Mã lỗi C6000 — Kyocera KM3035

Code: C6000

Description: Broken fixing heater wire • When the power is turned on or at the start of fixing control from the sleep mode, 10 s after fixing heater M is turned on, the detected temperature of fixing thermistor 2 is lower than 40 C/104 F. • When the power is turned on or at the start of fixing control from the sleep mode, 7 s after fixing heater S is turned on, the detected temperature of fixing thermistor 1 is lower than 40C/104 F. • During standby, the detected temperatures of fixing thermistors 1 and 2 become lower than 60 °C/140F
Causes: Poor contact in the fixing unit thermistor 1 or 2 connector terminals. Fixing unit thermistor 1 or 2 installed incorrectly. Fixing unit thermostat triggered. Fixing unit heater M or S installed incorrectly. Broken fixing unit heater M or S wire.
Remedy: Check the connection of connector YC10 on the main PCB and the continuity across the connector terminals. Repair or replace if necessary. Check and reinstall if necessary. Check for continuity. If none, replace the fixing unit thermostat. Check and reinstall if necessary. Check for continuity. If none, replace the fixing unit heater M or S.

← Xem tất cả mã lỗi Kyocera KM3035