Mã lỗi C6050 — Kyocera KM3035

Code: C6050

Description: Abnormally low fixing unit thermistor temperature • When only fixing heater M is on, fixing thermistor 2 detects temperature lower than 80 C/176 F during copying. • When fixing heater M and fixing heater S are on, fixing thermistor 2 detects temperature lower than 80 C/ 176 F or fixing thermistor 1 detects temperature lower than 100 C/212 F during copying.
Causes: Poor contact in the fixing unit thermistor connector terminals. Broken fixing unit thermistor wire. Fixing unit thermistor installed incorrectly. Fixing unit thermostat triggered. Fixing unit heater M or S installed incorrectly. Broken fixing unit heater M or S wire.
Remedy: Check the connection of connector YC10 on the main PCB and the continuity across the connector terminals. Repair or replace if necessary. Measure the resistance. If it is ∞Ω, replace the fixing unit thermistor. Check and reinstall if necessary. Check for continuity. If none, replace the fixing unit thermostat. Check and reinstall if necessary. Check for continuity. If none, replace the fixing unit heater M or S.