Code: C4000
Description: Polygon motor synchronization problem
• When the polygon motor starts, the motor does not become stable even after 20 s.
• When the polygon motor starts, the motor does not become stable even after 20 s.
Causes: Poor contact in the polygon motor connector terminals. Defective polygon motor. Defective power source PCB. Defective main PCB.
Remedy: Reinsert the connector. Also check for continuity within the connector cable. If none, remedy or replace the cable. Replace the LSU. Check if 24 V DC is supplied to CN2-1 on the main PCB. If not, replace the power source PCB. Check if 24 V DC is output from CN8-10 on the main PCB. If not, replace the main PCB.