Code: C8190
Description: Finisher trailing edge registration motor problem
• If the trailing edge registration home position sensor is on in initialization, the sensor does not turn off within 570 ms of starting initialization.
• If the trailing edge registration home position sensor is off in initialization, the sensor does not turn on within 4550 ms of starting initialization.
• If the trailing edge registration home position sensor is on in initialization, the sensor does not turn off within 570 ms of starting initialization.
• If the trailing edge registration home position sensor is off in initialization, the sensor does not turn on within 4550 ms of starting initialization.
Causes: The trailing edge registration motor connector makes poor contact. The trailing edge registration motor malfunctions. The trailing edge registration home position sensor connector makes poor contact. The trailing edge registration home position sensor malfunctions. Defective finisher main PCB.
Remedy: Reinsert the connector. Also check for continuity within the connector cable. If none, remedy or replace the cable. Replace the trailing edge registration motor and check for correct operation. Reinsert the connector. Also check for continuity within the connector cable. If none, remedy or replace the cable. Replace the trailing edge registration home position sensor and check for correct operation. Replace the finisher main PCB and check for correct operation.