Code: C1040
Description: Desk lower lift motor problem
• When the lower drawer of the paper feed desk is inserted, the desk lower lift limit switch does not turn on within 6 s of the desk lower lift motor turning on and the desk lower lift limit switch does not turn on by turning off the desk lower lift motor for 200 ms and retrying twice.
• During copying, the desk lower lift limit switch does not turn on within 200 ms of the desk lower lift motor turning on.
• When the lower drawer of the paper feed desk is inserted, the desk lower lift limit switch does not turn on within 6 s of the desk lower lift motor turning on and the desk lower lift limit switch does not turn on by turning off the desk lower lift motor for 200 ms and retrying twice.
• During copying, the desk lower lift limit switch does not turn on within 200 ms of the desk lower lift motor turning on.
Causes: Broken gears of couplings of the desk lower lift motor. Defective desk lower lift motor. Poor contact of the desk lower lift motor connector terminals. Defective desk lower lift limit switch. Poor contact of the desk lower lift limit switch connector terminals.
Remedy: Replace the desk lower lift motor. Check for continuity across the coil. If none, replace the desk lower lift motor. Reinsert the connector. Also check for continuity within the connector cable. If none, repair or replace the cable. Check if CN1-7 on the desk main PCB goes low when the desk lower lift limit switch is turned off. If not, replace the desk lower lift limit switch. Reinsert the connector. Also check for continuity within the connector cable. If none, repair or replace the cable.