Mã lỗi C6000 — Kyocera KM4030

Code: C6000

Description: Broken fixing heater wire
• After secondary stabilization, detected temperature of the fixing thermistor is lower than 100 C/212 F
• When the fixing heater is turned on, the output voltage of terminal CN2-1 of the power supply PCB is lower than 0.2 V.
• 7 s after the fixing heater is turned on, the output voltage of terminal CN2-1 of the power supply PCB is lower than 0.2 V.
• When the output voltage of terminal CN 2-1 of the power supply PCB is checked every 45 s during continuous copying, the voltage becomes lower than 0.2 V.
• When the fixing temperature becomes lower than 140 C/284 F during copying, the output voltage of terminal CN 2-1 of the power supply PCB is checked and the voltage is lower than 0.2 V.
Causes: Poor contact in the fixing unit thermistor connector terminals. Fixing unit thermistor installed incorrectly. Fixing unit thermostat triggered. Fixing unit heater M or S installed incorrectly. Broken fixing unit heater M or S wire.
Remedy: Check the connection of connector CN10 on the main PCB and the continuity across the connector terminals. Repair or replace if necessary. Check and reinstall if necessary. Check for continuity. If none, replace the fixing unit thermostat. Check and reinstall if necessary. Check for continuity. If none, replace the fixing unit heater M or S.