Description: Finisher paper conveying motor problem (3000-sheet finisher) • The paper conveying motor lockup signal is detected for 0.5 s or longer.
Causes: Poor contact in the paper conveying motor connector terminals. The paper conveying motor malfunctions. Defective finisher main PCB.
Remedy: Reinsert the connector. Also check for continuity within the connector cable. If none, remedy or replace the cable. Replace the paper conveying motor and check for correct operation. Replace the finisher main PCB and check for correct operation.