Code: C4010
Description: Polygon motor steady-state problem • The polygon motor rotation is not stable for 600 ms after the polygon motor rotation has been stabilized.
Causes: Poor contact in the polygon motor connector terminals. Defective polygon motor. Defective power source PCB. Defective engine PCB.
Remedy: Reinsert the connector. Also check for continuity within the connector cable. If none, remedy or replace the cable. Replace the LSU. Check if 24 V DC is supplied to CN1-4 on the main PCB. If not, replace the power source PCB. Check if 24 V DC is output from CN14-14 on the engine PCB. If not, replace the main PCB.