Code: E020
Description: Counter Error
Causes: The Counter Connection Detection Signal (COUNT_OPN) continues to be “L” for 1 second or longer after turning on.
Remedy: Wires 1 Is the wire between Counter and PW10520 PWB connected properly? No Connect it properly. Confirm that the machine is turned on, and then check the voltage of the orange line (J220-5). Is it 24V? No Replace the DC Power Supply if there is no problem with the wires. DC Power Supply (DCP1) or Fuse 2 Confirm that the machine is turned off, and then check whether or not each Fuse is broken. Is any Fuse broken? Yes Replace the Fuse. Counter 3 Check the operation of Counter in the Device Operation Mode of the Service Mode. Signal Code : 26 (Counter) Does the Counter operate correctly? No Replace the Counter.