Code: E032
Description: Separation Corona Output Error
Causes: The Separation Corona Output Detection Signal (AC_LD) continues to be “L” for 1 second or longer when the Separation Corona is ON.
Remedy: Wires 1 Are wires among Image Corona, HV Power Supply PWB and PW10520 PWB connected properly? No Connect them properly. Is the Image Corona dirty? Yes Clean each Corona Wire, Grid Plate and housing. Image Corona 2 Is the Corona Wire broken? Yes Replace the Corona Wire. Is the Transfer Corona dirty? Yes Clean each Corona Wire and housing. Transfer Corona 3 Is the Corona Wire broken? Yes Replace the Corona Wire. Is the Separation Corona dirty? Yes Clean each Corona Wire and housing. Separation Corona 4 Is the Corona Wire broken? Yes Replace the Corona Wire. HV Power Supply 5 Can you fix the problem if you replace the HV Power Supply? Yes OK