Mã lỗi C5500 — Kyocera KM4850w

Code: C5500

Description: Drum surface potential sensor error • Potential sensor input to CN2-5 on the engine main PCB was less than 500 V (3.1 V) (average of 15 inputs) during surface potential correction executed when copying starts or when the detachable unit, eject cover or lower right cover is opened/closed.
Causes: The drum surface potential sensor connector terminals make poor contact. The drum surface potential sensor is defective. The drum surface potential PCB is defective. The main charger wire is broken. The main charger grid is broken. The main high-voltage transformer connector terminals are loosely connected or are making poor contact. The main high-voltage transformer is defective. The engine main PCB is defective.
Remedy: Check for continuity across the connector terminals and remedy if necessary. Replace the drum surface potential sensor and the drum surface potential PCB and check for correct operation. Replace the drum surface potential sensor and the drum surface potential PCB and check for correct operation. Replace the main charger wire. Replace the main charger grid. Reinsert the connector. Also check for continuity across the terminal wire and if none, remedy or replace the wire. Replace the main high-voltage transformer and check for correct operation. Replace the engine main PCB and check for correct operation.