Thương hiệu phân phối chính hãng
Giỏ hàng

Mã lỗi C7200 — Kyocera KM4850w

Code: C7200

Description: Broken developing thermistor connection • The temperature detected by the developing thermistor was 0°C or lower for 100 ms. • The temperature detected by the developing thermistor was 56°C or higher for 100 ms.
Causes: The developing thermistor is not installed correctly. The developing thermistor connector terminals are loosely connected. The developing thermistor has a break. The developing thermistor has shorted.
Remedy: Check and reinstall if necessary. Check the connection of CN2-1 on the engine main PCB and continuity across the terminals. If there is abnormality, remedy or replace. Measure the resistance. If the resistance is  ∞Ω, replace the developing thermistor. Measure the resistance. If the resistance is 0Ω, replace the developing thermistor.

← Xem tất cả mã lỗi Kyocera KM4850w