Mã lỗi C6000 — Kyocera KM5050

Code: C6000

Description: Fuser heater break Fuser unit thermistor 1 detected less than 70C/158F for 10 s during warm-up and ready in. During warm-up, the temperature at the fuser unit themistor 1 does not rise by 1C/1.8F continuously for 5 s. Fuser unit thermistor 2 detected less than 40C/104F for 10 s during warm-up and ready in. During warm-up, the temperature at the fuser unit themistor 2 does not rise by 1C/1.8F continuously for 5 s.
Causes: Defective fuser heater M or S. Installation defectiveness on fuser unit thermistor 1. Defective fuser unit thermostat. Defective PWB.
Remedy: Defective fuser heater M or S. Replace the fuser heater M or S. Installation defectiveness on fuser unit thermistor 1. Check the mounting state of the fuser unit thermistor 1. If any problem is found, repair it. Defective fuser unit thermostat. Replace the fuser unit thermostat. Defective PWB. Replace the power source PWB or engine PWB and check for correct operation.