Code: C6020
Description: Abnormally high fixing unit thermistor temperature • The fixing temperature exceeds 220C/446 F for 10 s. • The fixing unit temperature detection circuit on the engine PCB detects and abnormally high temperature.
Causes: Shorted fixing unit thermistor. Broken fixing heater control circuit on the power source PCB.
Remedy: Measure the resistance. If it is 0 Ω, replace the fixing unit thermistor. Replace the power source PCB and check for correct operation.