Code: C3300
Description: Optical system (AGC) problem • After AGC, correct input is not obtained at CCD.
Causes: Insufficient exposure lamp luminosity. Defective scanner PWB. Incorrect shading position. CCD PWB output problem. Poor contact of the connector terminals.
Remedy: Insufficient exposure lamp luminosity. Replace the exposure lamp or inverter PWB. Defective scanner PWB. Replace the scanner PWB and check for correct operation. Incorrect shading position. Adjust the position of the contact glass (shading plate). If the problem still occurs, replace the scanner home position sensor. CCD PWB output problem. Replace the ISU. Poor contact of the connector terminals. Check the connection of connectors YC5, YC6 and YC8 on the SHD PWB and YC1, YC2 and YC3 on the CCD PWB, and the continuity across the connector terminals. Repair or replace if necessary.