Code: C5600
Description: Drum surface potential problem 1 • Grid voltage at 4.5 V could not determine the potential. • Potential adjustment in 30 times could not raise the potential sensor value to the predetermined.
Causes: Deteriorated main charger. Grid or main charger shield is dirty. Defective drum surface potential sensor. Defective high voltage PWB. Defective engine PWB.
Remedy: Deteriorated main charger. Check the main charger wire and replace it if necessary. Grid or main charger shield is dirty. Clean the grid or main charger shield if necessary. Defective drum surface potential sensor. Replace the drum surface potential sensor. Defective high voltage PWB. Replace the high voltage PWB and check for correct operation. Defective engine PWB. Replace the engine PWB and check for correct operation.