Code: C401
Description: Polygon motor steady-state problem • The polygon motor rotation is not stable for 600 ms after the polygon motor rotation has been stabilized.
Causes: Poor contact in the polygon motor connector terminals. Defective polygon motor. Defective power source PCB. Defective engine PCB.
Remedy: Reinsert the connector. Also check for continuity within the connector cable. If none, remedy or replace the cable. Replace the LSU. Check if 24 V DC is supplied to CN16-5 on the engine PCB. If not, replace the power source PCB. Check if 24 V DC is output from CN15-1 on the engine PCB. If not, replace the engine PCB.