Code: C1050
Description: Large paper deck right lift motor problem • When the large paper deck is inserted, the large paper deck level switch 1 does not turn on within 30 s of the deck right lift motor turning on. • During copying, the large paper deck level switch 1 does not turn on within 200 ms of the deck right lift motor turning on.
Causes: Broken gear or coupling of the large paper deck right lift motor. Defective large paper deck right lift motor. Poor contact in the large paper deck right lift motor connector terminals. Defective large paper deck level switch 1. Poor contact in the large paper deck level switch 1 connector terminals.
Remedy: Replace the large paper deck right lift motor. Check for continuity across the coil. If none, replace the large paper deck right lift motor. Reinsert the connector. Also check for continuity within the connector cable. If none, remedy or replace the cable. Check if CN13-A9 on the engine PCB goes low when large paper deck level switch 1 is turned on. If not, replace large paper deck level switch 1. Reinsert the connector. Also check for continuity within the connector cable. If none, remedy or replace the cable.