Code: C1150
Description: Side deck lift motor (going down) problem • When the side deck’s right cover is closed, the lower limit detection switch does not turn on within 17 s of the side deck lift motor turning on. • When the lower limit detection switch detects edge of turning off signal, the lower limit detection switch does not turn on within 200 ms of the side deck lift motor turning on.
Causes: Poor contact in the lower limit detection switch connector terminals. Defective lower limit detection switch. Defective side deck main PCB.
Remedy: Reinsert the connector. Also check for continuity within the connector cable. If none, remedy or replace the cable. Replace the lower limit detection switch. Replace the side deck main PCB.