Code: C8190
Description: Lower side-registration guide problem • During initialization, the front/rear lower side-registration guides are not detected in the home position within 1.5 s after the guide returns to the home position. JAM87 is indicated the first time this problem occurs. If the problem occurs after initialization when the front cover is opened and closed, the problem is in the lower side-registration guide. • When the lower side-registration guide is operated from the home position, the lower side-registration home position sensor does not turn off within 500 ms.
Causes: Loose connection of the lower sideregistration guide motor connector. Malfunction of the lower sideregistration guide motor. Malfunction of the lower sideregistration guide home position sensor. Loose connection of the lower sideregistration guide home position sensor connector. Defective finisher main PCB.
Remedy: Reinsert the connector. Also check for continuity within the connector cable. If none, remedy or replace the cable. Replace the lower side-registration guide motor and check for correct operation. Replace the lower side-registration guide home position sensor and check for correct operation. Reinsert the connector. Also check for continuity within the connector cable. If none, remedy or replace the cable. Replace the finisher main PCB and check for correct operation.