Code: C2200
Description: Drive motor error • LOCK signal remains high for 1 s, 1 s after the drive motor has turned on.
Causes: Poor contact in the drive motor connector terminals. Defective drive motor rotation control circuit. Defective drive transmission system. Defective deck PWB or engine PWB.
Remedy: Poor contact in the drive motor connector terminals. Check the connection of connector YC2 and YC11 on the deck PWB. Reinsert the connector. Also check for continuity within the connector cable. If none, remedy or replace the cable. Defective drive motor rotation control circuit. Replace the drive motor. Defective drive transmission system. Check if the rollers and gears rotate smoothly. If not, grease the bushings and gears. Check for broken gears and replace if any. Defective deck PWB or engine PWB. Replace the deck PWB or the engine PWB.