Code: C0061
Description: Fusing Drive Motor turning at abnormal timing
The Fusing Drive Motor Lock signal remains faulty for a predetermined continuous period of time while the Fusing Drive Motor remains stationary.
The Fusing Drive Motor Lock signal remains faulty for a predetermined continuous period of time while the Fusing Drive Motor remains stationary.
Remedy: 1 Fusing Drive Motor rotation while it is being energized: the voltage across PJ13I-1A on Master Board and GND remains DC 0 V. YES: Change Master Board. NO: Change motor.