Code: C0094
Description: 2nd Image Transfer Roller pressure/retraction failure
• The 2nd Image Transfer Pressure Position Sensor is not activated (retracted position) within 1 sec. after the 2nd Image Transfer Roller has started its retracting motion. • The 2nd Image Transfer Pressure Position Sensor is not deactivated (not the retracted position) within 1 sec. after the 2nd Image Transfer Roller has started its pressing motion.
• The 2nd Image Transfer Pressure Position Sensor is not activated (retracted position) within 1 sec. after the 2nd Image Transfer Roller has started its retracting motion. • The 2nd Image Transfer Pressure Position Sensor is not deactivated (not the retracted position) within 1 sec. after the 2nd Image Transfer Roller has started its pressing motion.
Remedy: 1 While the 2nd Image Transfer Pressure/ Retraction Clutch is supposed to be deenergized during timing of pressure/retraction operation: the voltage across PJ14I-9A on Master Board and GND is DC 24 V when the clutch is deenergized and DC 0 V when the clutch is energized. YES: Check connector for connection. Check for overload. Change clutch. NO: Change Master Board. 2 I/O check for 2nd Image Transfer Pressure Position Sensor operation during pressure/ retraction operation: the voltage across PJ14I-6B on Master Board and GND is DC 0 V when the sensor is unblocked and DC 5 V when the sensor is blocked (pressed position). YES: Change Master Board. NO: Correct actuator. Check sensor connector for connection. Change sensor.