Code: C0096
Description: 1st Image Transfer Roller pressure/retraction failure
• The 1st Image Transfer Retraction Position Sensor is not activated (retracted position) within 3 sec. after the 1st Image Transfer Pressure/Retraction Motor has started turning. • The 1st Image Transfer Retraction Position Sensor is not deactivated (pressed position) within 1.5 sec. after the 1st Image Transfer Pressure/Retraction Motor has started turning.
• The 1st Image Transfer Retraction Position Sensor is not activated (retracted position) within 3 sec. after the 1st Image Transfer Pressure/Retraction Motor has started turning. • The 1st Image Transfer Retraction Position Sensor is not deactivated (pressed position) within 1.5 sec. after the 1st Image Transfer Pressure/Retraction Motor has started turning.
Remedy: 1 1st Image Transfer Pressure/Retraction Motor turns during pressure/retraction operation. NO: Check connector for connection. Correct drive coupling (drive transmitting gear engagement). Change motor. Change Master Board. 2 I/O check for 1st Image Transfer Retraction Position Sensor operation during pressure/ retraction operation: the voltage across PJ17I-1A on Master Board and GND is DC 0 V when the sensor is unblocked and DC 5 V when the sensor is blocked (retracted position). YES: Change Master Board. NO: Correct actuator. Check sensor connector for connection. Change sensor.