Code: C0501
Description: Lower Fusing Roller Heater Lamp warm-up failure (Fusing Thermistor 2)
•The temperature of Fusing Thermistor 2 does not reach 100 C within 180 sec. after the warm-up cycle has started. • The temperature of Fusing Thermistor 1 does not rise to a level more than the predetermined output value within 130 sec. after the warm-up cycle has started.
•The temperature of Fusing Thermistor 2 does not reach 100 C within 180 sec. after the warm-up cycle has started. • The temperature of Fusing Thermistor 1 does not rise to a level more than the predetermined output value within 130 sec. after the warm-up cycle has started.
Remedy: 1 Fusing Unit condition: the resistance across CN4-17 and 18 on the Fusing Unit end is infinity with CN4 (2P) disconnected. YES: Change Fusing Unit. NO: Change Master Board. 2 Lower Fusing Roller Heater Lamp turns ON. YES: Change DC Power Supply 1. Change Master Board. NO: Change Fusing Unit.