Code: C0511
Description: Lower Fusing Roller Heater Lamp abnormally low temperature (Fusing Thermistor 2)
• The temperature of Fusing Thermistor 2 remains below 100 C for 1 sec. or more in the standby state. • The temperature of Fusing Thermistor 2 remains below 100 C for 1 sec. or more during a print cycle. • The temperature of Fusing Thermistor 2 remains below 100 C for 1 sec. or more in the Energy Saver mode.
• The temperature of Fusing Thermistor 2 remains below 100 C for 1 sec. or more in the standby state. • The temperature of Fusing Thermistor 2 remains below 100 C for 1 sec. or more during a print cycle. • The temperature of Fusing Thermistor 2 remains below 100 C for 1 sec. or more in the Energy Saver mode.
Remedy: 1 Fusing Unit condition: the resistance across CN4-17 and 18 on the Fusing Unit end is infinity with CN4 (2P) disconnected. YES: Change Fusing Unit. NO: Change Master Board. 2 Lower Fusing Roller Heater Lamp turns ON. YES: Change DC Power Supply 1. Change Master Board. NO: Change Fusing Unit.