Code: C3310
Description: CCD clamp/gain adjustment failure
• When clamp adjustment is made: (AVE1 -AVE2) =< 4 • When gain adjustment is made: The average of CCD Sensor output values is 1 or less. Dgain = 0 Dgain = 255
• When clamp adjustment is made: (AVE1 -AVE2) =< 4 • When gain adjustment is made: The average of CCD Sensor output values is 1 or less. Dgain = 0 Dgain = 255
Remedy: 1 Check that each of the values displayed on the screen falls within the above range. 2 There is a wide difference between the clamp and gain adjustment values, the value being close to “0” or “255.” YES: Make positive connection of the harness connectors between CCD Sensor Board and Image Processing Board. 3 Clamp adjustment value exceeds the allowable range. YES: Reinstall covers, as extraneous light is the cause of the problem. 4 The lamp adjustment value or gain value exceeds the upper limit of the allowable range, being abnormally great. YES: Clean lens, mirrors, CCD surface, shading sheet, and related parts. 5 The lamp adjustment value or gain value falls short of the lower limit of the allowable range, being abnormally small. YES: Reinstall covers, as extraneous light is the cause of the problem. Change Scanner, as the reflectors are deformed.