Mã lỗi C3A00 — Kyocera KMC2030

Code: C3A00

Description: PIC communication error
• A sampling lock is not received after the lapse of a predetermined period of time after IREQ has been received during AIDC sampling of image stabilization sequence or registration adjustment. • There is an open-circuit in the communication harness between the PIC Board and Master Board. • Either the PIC Board or Master Board is faulty.
Remedy: 1 Harnesses and connectors connecting PIC Board to Master Board are in good condition. NO: Change harnesses. Reconnect connectors. 2 The problem has been eliminated through the check of step 1. NO: Change PIC Board. 3 The problem is eliminated after the PIC Board has been replaced. NO: Change Master Board.oard.