Code: C3200
Description: Exposure lamp problem • Check the CCD input value for the lighting status of the exposure lamp 500 ms after the exposure lamp is lit and the carriage is moved to the shading position. If the exposure lamp does not light, a further 100 ms later, check the CCD input. The exposure lamp does not light after 50 retries.
Causes: Defective scanner main PWB. Defective exposure lamp or inverter PWB. Incorrect shading position. Poor contact of the connector terminals. Defective scanner sub PWB or CCD PWB.
Remedy: Defective scanner main PWB. Replace the scanner main PWB and check for correct operation. Defective exposure lamp or inverter PWB. Replace the exposure lamp or inverter PWB. Incorrect shading position. Adjust the position of the contact glass (shading plate). If the problem still occurs, replace the scanner home position switch. Poor contact of the connector terminals. Check the connection of connector YC19 on the scanner main PWB, and the continuity across the connector terminals. Repair or replace if necessary. Defective scanner sub PWB or CCD PWB. Replace the scanner sub PWB or CCD PWB and check for correct operation.