Mã lỗi C6000 — Kyocera KMC2630D

Code: C6000

Description: Upper fuser heater lamp break • The time for increasing the temperature at the upper fuser heater lamp to 60 C/140 F during warm-up exceeds 100 s from the start of warm-up. Then, the time for increasing the temperature from 60 C/140 F to 120 C/248 F exceeds 100 s.
Causes: Installation defectiveness on upper fuser thermistor. Defective upper fuser thermostat. Defective engine controller PWB. Defective power supply PWB. Defective fuser PWB. Connected malfunction of electric wire on upper fuser thermistor or connected malfunction of connector terminal. Defective upper fuser heater lamp.
Remedy: Installation defectiveness on upper fuser thermistor. Check the mounting state of the upper fuser thermistor. If any problem is found, repair it. Defective upper fuser thermostat. Replace the upper fuser thermostat. Defective engine controller PWB. Replace the engine controller PWB. Defective power supply PWB. Replace the power supply PWB. Defective fuser PWB. Replace the fuser PWB. Connected malfunction of electric wire on upper fuser thermistor or connected malfunction of connector terminal. Check the cable of the upper fuser thermistor and the connection of the fuser PWB for any problem. If any problem is found, repair it. Defective upper fuser heater lamp. Replace the upper fuser heater lamp.

← Xem tất cả mã lỗi Kyocera KMC2630D